Improvement of a plastic scintillator with different coatings for gamma-ray detection
Por:
Méndez-García J., Alva-Sánchez H., Alvarez-Núñez L.C., Chavéz E., Farah-Simon A., García-Flores A., Huerta A., López-López O., Marín-Lámbarri D.J., Murrieta-Rodriguez T., Valencia C.
Publicada:
1 ene 2025
Resumen:
Identical cubic plastic scintillator detectors were tested using different coating materials in order to investigate their response function and efficiency, additionally two light guides were also coated evaluating their performance in order to find the best combination for a detection array. The array is composed by a plastic scintillator coupled to a light guide and a photomultiplier tube (PMT), the output signal is processed by a Data Aquisition System (DAQ). Operational voltage for the PMT was found and detectors were tested measuring 137Cs certified gamma-ray point source. Spectra were analyzed and optimal coating for light guide and detector combination was determined based on the arraya's efficiency. © The Authors, published by EDP Sciences, 2025.
Filiaciones:
Méndez-García J.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Alva-Sánchez H.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Alvarez-Núñez L.C.:
Instituto de Astronomia, Universidad Nacional Autónoma de México, Ciudad de Mexico, Mexico
Chavéz E.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Farah-Simon A.:
Instituto de Astronomia, Universidad Nacional Autónoma de México, Ciudad de Mexico, Mexico
García-Flores A.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Huerta A.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
López-López O.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Marín-Lámbarri D.J.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Murrieta-Rodriguez T.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
Valencia C.:
Instituto de Física, Universidad Nacional Autónoma de México, Apartado Postal 20-364, Ciudad de México, 01000, Mexico
gold
|