Mathematical model of the QUENCH-06 experiment with sensitivity and uncertainty analysis in hydrogen generation
Por:
Sanchez-Mora, Heriberto, Ortiz-Villafuerte, Javier, Gomez-Torres, Armando M., Queral, Cesar, Quezada-Garcia, Sergio
Publicada:
1 ene 2023
Resumen:
During the cooling of the reactor core, as a result of a severe
accident, a strongly exothermic oxidation reaction of the zirconium
cladding occurs and leads to hydrogen production, this has been observed
in Fukushima, Chernobyl and Three Mile Island accidents. Several
experiments have been carried out for the understanding of the phenomena
that are involved in a severe accident and of the adequate mathematical
modeling of the behavior of these scenarios. The objective of this work
is to develop a reduced model of low computational cost that simulates
the cooling phenomenon considering the heat transfer for the fuel rods,
the thermohydraulic phenomena in the coolant, and the hydrogen
generation focus on the QUENCH-06 experiment, where the purpose of this
experiment is to investigate the cooling process of fuel rods in a
severe accident scenario in a light-water nuclear reactor. The reduced
model is solved numerically. It is implemented in a C++ compiler and it
is validated with the data of the experiment, obtaining a deviation in
the integral hydrogen generation of -4.7%. Subsequently, a sensitivity
and uncertainty analysis is carried out to determine the parameters
involved with greater relevance in the integral hydrogen generation. The
results show that the variables with the greatest impact on hydrogen
generation are: the variation of the steam flow, the convective heat
transfer coefficient, and the inlet temperature of steam and argon, the
latter with the largest value of the Pearson's correlation coefficient.
(C) 2022 Elsevier Ltd. All rights reserved.
Filiaciones:
Inst Politecn Nacl, Escuela Super Fis & Matemat Gustavo A Madero, Mexico City 07738, DF, Mexico
Inst Nacl Invest Nucl, Carretera Mexico Toluca,Marquesas S-N, Ocoyoacac 52750, Estado De Mexic, Mexico
Univ Politecn Madrid, Madrid 28040, Spain
Univ Nacl Autonoma Mexico, Fac Ingn, Ciudad Univ,Ave Univ 3000, Mexico City 04510, DF, Mexico