Fluorescence Spectroscopy as a Tool for the Assessment of Liver Samples with Several Stages of Fibrosis


Por: Fabila-Bustos D.A., Arroyo-Camarena U.D., López-Vancell M.D., Durán-Padilla M.A., Azuceno-García I., Stolik-Isakina S., Valor-Reed A., Ibarra-Coronado E., Hernández-Quintanar L.F., Escobedo G., De La Rosa-Vázquez J.M.

Publicada: 1 mar 2018
Resumen:
During the last years, fluorescence spectroscopy has been used as a potential tool for the evaluation and characterization of tissues with different disease conditions due to its low cost, high sensitivity, and minimally or noninvasive character. In this study, fluorescence spectroscopy was used to study 19 paraffin blocks containing human liver tissue from biopsies. All samples were previously analyzed by two senior pathologists in a single-blind trial. After their evaluation, four liver samples were classified as nonfibrosis (F0), four as initial fibrosis (F1-F2), four as advanced fibrosis (F3), and six as cirrhosis (F4). The fluorescence was induced at different wavelengths as follows: 330, 365, and 405nm using a portable fiber-optic system. The fluorescence spectra were recorded in the range of 400-750nm. A distinctive correlation between the shape of each spectrum and the level of fibrosis in the liver sample was detected. A multi-variate statistical analysis based on principal component analysis followed by linear discrimination analysis was applied to develop algorithms able to distinguish different stages of fibrosis based on the characteristics of fluorescence spectra. Pairwise comparisons were performed: F0 versus F1-F2, F1-F2 versus F3, F3 versus F4, and F1-F2 versus F4. The algorithms applied to each set of data yielded values of sensitivity and specificity that were higher than 90% and 95%, respectively, in all the analyzed cases. With this study, it is concluded that fluorescence spectroscopy can be used as a complementary tool for the assessment of liver fibrosis in liver tissue samples, which sets the stage for subsequent clinical trials.

Filiaciones:
Inst Politecn Nacl, UPIIH, Lab Espect, Ciudad Conocimiento & Cultura, San Agustin Tlaxiaca, Hidalgo, Mexico
Inst Politecn Nacl, ESIME Zac, Lab Biofoton, Mexico City 07738, DF, Mexico
Univ Nacl Autonoma Mexico, Hosp Gen Mexico Dr Eduardo Liceaga, Fac Med, Unidad Med Expt, Mexico City, DF, Mexico
Hosp Gen Mexico Dr Eduardo Liceaga, Serv Patol, Mexico City, DF, Mexico
Univ Nacl Autonoma Mexico, Dept Inmunol, Inst Invest Biomed, Ciudad Univ, Mexico City, DF, Mexico
Univ Tecnol Mexico, UNITEC MEXICO, Campus Sur, Mexico City, DF, Mexico
Laboratorio de Espectroscopía, UPIIH, Ciudad Del Conocimiento y la Cultura, Instituto Politécnico Nacional, San Agustín Tlaxiaca, Hidalgo, Mexico
Laboratorio de Biofotónica, ESIME Zac, Instituto Politécnico Nacional, Ciudad de Mexico, 07738, Mexico
Unidad de Medicina Experimental, Facultad de Medicina, Universidad Nacional Autónoma de Méxic, Hospital General de México dr. Eduardo Liceaga, Ciudad de México, Mexico
Servicio de Patología, Hospital General de México Dr. Eduardo Liceaga, Ciudad de México, Mexico
Departamento de Inmunología, Instituto de Investigaciones Biomédicas, Ciudad Universitaria, Universidad Nacional Autónoma de México, Ciudad de México, Mexico
Universidad Tecnológica de México-UNITEC Mexico - Campus sur, Ciudad de México, Mexico
ISSN: 15495418
Editorial
MARY ANN LIEBERT INC, 140 HUGUENOT STREET, 3RD FL, NEW ROCHELLE, NY 10801 USA, Estados Unidos America
Tipo de documento: Article
Volumen: 36 Número: 3
Páginas: 151-161
WOS Id: 000416446800001
ID de PubMed: 29131710

MÉTRICAS